Sprinkler System Design
Wet, dry, pre-action, and antifreeze systems. Full layout, riser, and equipment details.
EverSafe Fire Protection offers six core services. A Florida-licensed Professional Engineer prepares or reviews every deliverable. You get sealed, permit-ready documents for projects across Central Florida and statewide.
NFPA 13 · FBC
We design fire sprinkler systems for commercial, industrial, and mission-critical buildings. Drawings and calculations are PE-stamped and ready for permit.
Best for: MEP firms, architects, and sprinkler contractors who need a sealed sprinkler design or delegated design.
Wet, dry, pre-action, and antifreeze systems. Full layout, riser, and equipment details.
We size the system and check it against the available water supply and flow test data.
Sprinkler design for warehouses and storage areas based on commodity, height, and arrangement.
High-piled storage →Sealed shop drawings for delegated-design submittals, coordinated with your architectural and MEP plans.
NFPA 72 · FBC
We design complete fire alarm and detection systems. Every package includes the calculations and sequence the AHJ asks for.
Best for: MEP firms, alarm contractors, and owners doing new construction or renovations.
Detection, notification, and control device layout, plus a clear system riser.
Standby and alarm battery sizing, and voltage-drop checks for each notification circuit.
An input/output matrix that shows what each device does in an alarm.
Drawings, calculations, and data sheets, sealed and ready for permit.
NFPA 101 · NFPA 101A · FBC
We prepare life safety plans and egress analysis for permit. We show how people get out safely and how the building limits fire and smoke.
Best for: Architects, owners, and healthcare or education facilities that need life safety sheets or a code evaluation.
AHJ-ready life safety sheets for building permits and renovations.
Occupancy classification, occupant load, exit capacity, and travel distance.
Rated walls, smoke compartments, and opening protection shown clearly on plan.
NFPA 101A equivalency worksheets for existing buildings that cannot meet every prescriptive rule.
PE Seal · NFPA 13 / 72
You made the drawings. We review them, fix code issues, and seal them. Your submittal gets the PE certification the AHJ requires.
Best for: Design-build sprinkler and alarm contractors, and MEP firms without a fire protection engineer on staff.
Independent review of sprinkler and fire alarm drawings against NFPA 13, NFPA 72, and the FBC.
Once the package is compliant, we sign and seal it for permit.
We answer plan review comments and support revisions until approval.
FFPC · FBC · IFC Ch. 50
We answer hard code questions and prepare hazmat documents for permit. We help you find a compliant path before design gets expensive.
Best for: Owners, labs, manufacturers, and design teams with code conflicts or hazardous materials.
Code analysis and clear answers on fire protection requirements for your building.
Engineering support for AHJ requests when the code path does not fit your project.
Material classification and quantity tables by control area for hazmat permits.
HMIS →We compare your stored and used quantities to the limits in IFC Table 5003.1.1.
MAQ analysis →NFPA 855 · NFPA 2001 · FBC 909
We protect high-value and high-risk spaces. When prescriptive code is not enough, we use performance-based fire and smoke modeling.
Best for: Data centers, battery energy storage, and facilities with unusual hazards or large open spaces.
Fire protection strategy for spaces where downtime is not an option.
Fire protection and code compliance for battery energy storage systems.
Clean agent system design for rooms that cannot use water.
Performance-based fire and smoke models to prove tenable conditions.
Fire and smoke modeling →Smoke control rational analysis for atriums and other large spaces.
Smoke control studies →| If you need… | Choose |
|---|---|
| A new sprinkler design or hydraulic calcs | 01 · Fire Sprinkler Design |
| A new fire alarm design | 02 · Fire Alarm Design |
| Life safety sheets, egress analysis, or an FSES | 03 · Life Safety & Egress |
| A PE seal on drawings your team already made | 04 · Plan Review & PE Stamping |
| A code answer, an HMIS, or an MAQ check | 05 · Code & Hazmat Compliance |
| Data center, battery storage, clean agent, or smoke modeling | 06 · Special Hazards & Modeling |
Six services: fire sprinkler system design, fire alarm and detection design, life safety and egress, plan review and PE stamping, code consulting and hazmat compliance, and special hazards and fire modeling.
Central Florida and projects statewide across Florida.
Yes. A Florida-licensed Professional Engineer prepares or reviews every deliverable. Drawings are sealed and permit-ready.
Yes. We review your sprinkler or fire alarm drawings, send marked-up comments, and seal the package once it is compliant.
Send plans or a short project summary. You usually get a fixed-fee proposal within one business day.
Per project, per sheet, or on an ongoing retainer.
Send plans or a project summary and you'll have a clear fixed-fee proposal, usually within one business day.
Send plans or a short project summary and we'll get you a clear, fixed-fee proposal, usually within one business day.